温馨提示:请使用IE9及以上版本浏览器浏览本页内容
Inverter Air Water Heat Pump
VS Series
-
Advantage of POCAAX full DC Inverter air to water heat pump evi model monobloc type:
1. Full DC Inverter technology:
With Panasonic twin rotary compressor and also panasonic brushless inverter fan motor.
2. Evi Technology:
Evi technology is adopted so that unit can function well under low ambient temperature of -30 centigrade low temperature.
3. Wifi Control:
Wifi control is applicated in Lorgool full dc inverter heat pump system.
4. Warranty:
3 years on the whole system.
- 3D展示
- Introduction
- Specifications
- Installation
- Parts
POCAAX Full DC Inverter Heat Pump Monoblock Evi for R410A/R32 Series En14511 Standard Water Heaters with Energy lever A+++ Class. our DC inverter heat pumps save energy by more than 30% compared with other ordinary air source heat pumps. The maximum COP reaches 5.65!
Low Noise,with Panasonic rotary compressor and DC inverter brushless fans, our DC inverter heat pumps adopt new noise reduction measures so that the sound of the unit is controlled at a satisfactory level.
Low Noise,with Panasonic rotary compressor and DC inverter brushless fans, our DC inverter heat pumps adopt new noise reduction measures so that the sound of the unit is controlled at a satisfactory level.
Spec for Inverter Evi Air Source Heat Pump Split Type:
Split Type Households Low Temperature Inverter Air Source Heat Pump Unit Specification | ||||||
Whole Model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | ||
Cooling:(Outdoor dry bulb 35℃, outlet water 7℃) | Cooling Capacity | kW | 7.06 | 8.75 | 10.80 | 12.50 |
Input power | kW | 2.66 | 3.22 | 3.93 | 4.63 | |
EER | W/W | 2.65 | 2.71 | 2.75 | 2.70 | |
Heating:(Outdoor dry bulb/wet bulb 7℃/6℃, outlet water 45℃) | Heating Capacity | kW | 8.85 | 11.85 | 15.08 | 17.85 |
Input power | kW | 2.68 | 3.43 | 4.27 | 5.10 | |
COP | W/W | 3.30 | 3.45 | 3.53 | 3.50 | |
Heating:(Outdoor dry bulb/wet bulb -12℃/-14℃, outlet water 41℃) | Heating Capacity | kW | 6.02 | 8.42 | 10.53 | 12.65 |
Input power | kW | 2.41 | 3.35 | 4.13 | 4.96 | |
COP | W/W | 2.50 | 2.51 | 2.55 | 2.55 | |
Heating:(Outdoor dry bulb -20℃, outlet water 41℃) | Heating Capacity | kW | 4.85 | 7.45 | 9.35 | 11.23 |
Input power | kW | 2.36 | 3.47 | 4.23 | 5.15 | |
COP | W/W | 2.05 | 2.15 | 2.21 | 2.18 | |
Comprehensive partial load performance coefficient IPLV(C) | W/W | 3.77 | 3.88 | 3.85 | 3.90 | |
Comprehensive partial load performance coefficient IPLV(H) | W/W | 2.90 | 2.94 | 2.91 | 2.95 | |
Water System | Water pump | Built-in WILO DC INVERTER | ||||
Automatic exhaust valve | Built-in | |||||
Flow switch | Built-in | |||||
Water side heat exchanger | Species | Brazed plate heat exchanger ALFA LAVAL | ||||
Intake pipe/Outlet pipe | DN25 | DN32 | DN32 | |||
Water flow | m3/h | 1.2 | 1.5 | 1.85 | 2.15 | |
Water resistance | kPa | 39 | 45 | 45 | 45 | |
Noise | Outdoor unit | dB(A) | 59 | 60 | 62 | 62 |
Net weight | Outdoor unit | kg | 68 | 85 | 105 | 110 |
Size | Outdoor unit (L×W×H) | mm | 896*440*802 | 896*440*802 | 940*393*1368 | 940*393*1368 |
Cooling loop | Refrigerant | Model | R410A/R32 | |||
Filling quantity | kg | 1.7 | 2.5 | 3.2 | 4.0 | |
Compressor | Form | EVI DC Inverter Twin Rotary Panasonic | ||||
Quantity | 1 | |||||
Finned heat exchanger | Specifications | Efficient hydrophilic aluminum foil finned heat exchanger | ||||
Throttling way | Electronic expansion valve | |||||
Ventilation system | Motor | Form | DC Inverter | |||
Quantity | 1 | 2 | ||||
Power supply specifications | 220V~/50Hz | |||||
Max input current | A | 20 | 25 | 30 | 36 | |
Max outlet temperature | ℃ | 58 | ||||
Refrigerating operating range | ℃ | 15 ~ 46 | ||||
Heating operation range | ℃ | -26 ~ 25 | ||||
Noise | Indoor unit | dB(A) | 38 | 38 | 40 | 40 |
Net weight | Indoor unit | kg | 37 | 45 | 55 | 63 |
Size | Length*Thickness*Height | mm | 500x290x750 | 500x290x750 | 500x290x750 | 500x290x750 |
Installation Instruction for Reference:
Parts we are using:
POCAAX Monobloc full inverter evi air water cooling and heating heat pump adopts first class components to ensure that the unit can work in good conditions under low ambient temperature of -35 centigrade with high cop and low noise level. The key components we are using is: Full inverter twin rotary compressor from MITSUBISHI, PANASONIC or GMCC, inverter fan motor, ALFA LAVAL plate heater exchanger, digital touch controller with wifi.
POCAAX Monobloc full inverter evi air water cooling and heating heat pump adopts first class components to ensure that the unit can work in good conditions under low ambient temperature of -35 centigrade with high cop and low noise level. The key components we are using is: Full inverter twin rotary compressor from MITSUBISHI, PANASONIC or GMCC, inverter fan motor, ALFA LAVAL plate heater exchanger, digital touch controller with wifi.
Parts we are using:
POCAAX Monobloc full inverter evi air water cooling and heating heat pump adopts first class components to ensure that the unit can work in good conditions under low ambient temperature of -35 centigrade with high cop and low noise level. The key components we are using is: Full inverter twin rotary compressor from MITSUBISHI, PANASONIC or GMCC, inverter fan motor, ALFA LAVAL plate heater exchanger, digital touch controller with wifi.
POCAAX Monobloc full inverter evi air water cooling and heating heat pump adopts first class components to ensure that the unit can work in good conditions under low ambient temperature of -35 centigrade with high cop and low noise level. The key components we are using is: Full inverter twin rotary compressor from MITSUBISHI, PANASONIC or GMCC, inverter fan motor, ALFA LAVAL plate heater exchanger, digital touch controller with wifi.